Seals in PurgeX pumps normally operate over millions of cycles without significant wear.  The majority of applications do not require seal replacement.

 

This Viton Seal Replacement Kit is suitable for PurgeX models:

 

·          B3162-312

·          B3352-312

 

 

Replacement Procedure

 

PurgeX seals should be carefully replaced in a clean environment.  Remove the current seals from the unit.  Wash the remaining components with mineral spirits and allow them to dry completely.  Apply oil to the new seals before assembling.  Step by step assembly instructions can be downloaded using the link on this page.

 

Note: If the evacuation valve (A7440-2) is removed from the assembly at any time, it must be replaced with a new evacuation valve or the warranty is void.

 

 

Supplied Components:

Key

Part

Material

Location

Qty

A

A3395-1

Viton

Adjustment Stem

12

B

A3395-13

Viton

Adjustment Cap

12

C

A5074-17

Viton

Piston head

12

D

A3395-6

Viton

Piston Bore (Stationary Seal)

12

E

A4213-39

Viton

Shuttling O-Ring

12

F

A4213-37

Viton

Lower Piston Groove

12

G

A7440-2

Viton, Brass

Evacuation Valve

12

H

A3395-9

Viton

Outlet Adapter

12

I

A3395-9

Viton

Adapters/Threadapters

26

Seals

N/A Viton

Feeds

N/A 12 Feeds

Use With

N/A B3162-312

Use With

N/A B3352-312