Seals in PurgeX pumps normally operate over millions of cycles without significant wear.  The majority of applications do not require seal replacement.

 

This Buna Seal Replacement Kit is suitable for PurgeX models:

 

·          B3162-104

·          B3352-104

 

 

Replacement Procedure

 

PurgeX seals should be carefully replaced in a clean environment.  Remove the current seals from the unit.  Wash the remaining components with mineral spirits and allow them to dry completely.  Apply oil to the new seals before assembling.  Step by step assembly instructions can be downloaded using the link on this page.

 

 

Note: If the evacuation valve (A7440-1) is removed from the assembly at any time, it must be replaced with a new evacuation valve or the warranty is void.

 

 

Supplied Components:

 

 

Key

Part

Material

Location

Qty

A

A2699-1

Buna

Adjustment Stem

4

B

A2699-13

Buna

Adjustment Cap

4

C

A4939-17

Buna

Piston head

4

D

A2699-6

Buna

Piston Bore (Stationary Seal)

4

E

A4213-39

Viton

Shuttling O-Ring

4

F

A4213-38

Buna

Lower Piston Groove

4

G

A7440-1

Buna, Brass

Evacuation Valve

4

H

A2699-9

Buna

Outlet Adapter

4

I

A2699-9

Buna

Adapters/Threadapters

10

 

Seals

N/A Buna

Feeds

N/A 4 Feeds

Use With

N/A B3162-104

Use With

N/A B3352-104