Reservoir Selection
The Standard Hydracision® 2 liter reservoir can supply 36 lube points with oil every 30 minutes for 5 days without requiring a refill. Four reservoir sizes are available. The 2 liter polycarbonate reservoir can rest on its base or be mounted to a vertical surface. The 4, 12, and 20 liter reservoirs are steel and include a drain, low level switch, and liquid level gage for monitoring fluid level. The chart below estimates the number of 8 hour shifts that can be serviced by each size reservoir.
NUMBER OF 8 HOUR SHIFTS BETWEEN RESERVOIR REFILLS | |||||||||||||
|
|
2 LITER RESERVOIR |
4 LITER RESERVOIR |
12 LITER RESERVOIR |
20 LITER RESERVOIR | ||||||||
Number of Injectors |
Cycle Frequency |
Injector Volume Options |
Injector Volume Options |
Injector Volume Options |
Injector Volume Options | ||||||||
HIGH |
MEDIUM |
LOW |
HIGH |
MEDIUM |
LOW |
HIGH |
MEDIUM |
LOW |
HIGH |
MEDIUM |
LOW | ||
12 Injectors |
Once an Hour |
104 |
148 |
260 |
208 |
297 |
520 |
625 |
892 |
1562 |
1041 |
1488 |
2604 |
Every 30 Mins. |
52 |
74 |
130 |
104 |
148 |
260 |
312 |
446 |
781 |
520 |
744 |
1302 | |
Every 3 Mins. |
5 |
7 |
13 |
10 |
14 |
26 |
31 |
44 |
78 |
52 |
74 |
130 | |
Once a Min |
1 |
2 |
4 |
3 |
5 |
8 |
10 |
14 |
26 |
17 |
24 |
43 | |
36 Injectors |
Once an Hour |
34 |
49 |
86 |
69 |
99 |
173 |
208 |
297 |
520 |
347 |
496 |
868 |
Every 30 Mins. |
17 |
24 |
43 |
34 |
49 |
86 |
104 |
148 |
260 |
173 |
248 |
434 | |
Every 3 Mins. |
1 |
2 |
4 |
3 |
5 |
8 |
10 |
14 |
26 |
17 |
24 |
43 | |
Once a Min |
- |
- |
1 |
1 |
1 |
2 |
3 |
5 |
8 |
5 |
8 |
14 | |
72 Injectors |
Once an Hour |
17 |
- |
43 |
34 |
49 |
86 |
104 |
148 |
260 |
173 |
248 |
434 |
Every 30 Mins. |
8 |
12 |
21 |
17 |
24 |
43 |
52 |
74 |
130 |
86 |
124 |
217 | |
Every 3 Mins. |
- |
1 |
2 |
1 |
2 |
4 |
5 |
7 |
13 |
8 |
12 |
21 | |
Once a Min |
- |
- |
- |
- |
- |
1 |
1 |
2 |
4 |
2 |
4 |
7 |
Hydracision® includes a reservoir, control panel, centralized pump, low level switch, and injectors. Tubing and connectors are sold separately. A multi-point lubrication package is built to order from the following specifications: reservoir capacity, seal material, and number of injectors for each output volume (high/medium/low)
Sample Part Number |
B |
4 |
5 |
6 |
0 |
- |
0 |
2 |
B |
1 |
2 |
0 |
6 |
0 |
7 |
2 |
0 |
0 |
0 |
0 |
0 |
0 |
|||||||||||||||||||
Hydracision Packaged System | |||||||||||||||||||||||||||||||||||||||||
Reservoir Capacity in Liters: 02, 04, 12, 20 | |||||||||||||||||||||||||||||||||||||||||
Seal Material: B= Buna, V = Viton | |||||||||||||||||||||||||||||||||||||||||
Voltage: 120 = 120 V, 230 = 230V, 024 =24V | |||||||||||||||||||||||||||||||||||||||||
Frequency: 6 = 60Hz, 50 = 50Hz, D = DC | |||||||||||||||||||||||||||||||||||||||||
Number of High Volume Injectors - .20 ml | |||||||||||||||||||||||||||||||||||||||||
Number of Medium Volume Injectors - .14 ml | |||||||||||||||||||||||||||||||||||||||||
Number of Low Volume Injectors - .08 ml | |||||||||||||||||||||||||||||||||||||||||